Abstract
Objective To quantify the proportion of requests for colonoscopy that are performed as flexible sigmoidoscopy and documented reasons for this in ordinary UK hospital practice. To determine the effect these requests have on colonoscopy completion rate if they are included in the denominator of the calculated rate by individual endoscopist.
Design Retrospective study of 22 months flexible sigmoidoscopy practice at a major UK teaching hospital. All flexible sigmoidoscopies performed had their associated request form examined.
Setting UK NHS University Hospital.
Patients All patients receiving outpatient flexible sigmoidoscopy from January 2013 to October 2014 with no exclusions.
Intervention Conversion of colonoscopy to flexible sigmoidoscopy.
Main outcome measures Conversion of colonoscopy to flexible sigmoidoscopy, reason for conversion and adjusted colonoscopy completion rate.
Results 71 of the 3526 flexible sigmoidoscopies performed (2.0%), representing 71 of 5905 colonoscopy requests (1.2%). Conversion reason was noted only in 26 (37%) of converted cases. Adjustment of colonoscopy completion rate to include conversions pushed four of our unit's 22 endoscopists below the UK national 90% standard.
Conclusions Conversion to flexible sigmoidoscopy occurs in 1.2% of patients originally booked for colonoscopy. The reason for this conversion is often unqualified and may be inappropriate. Conversion can affect the colonoscopy completion rate, and therefore, should be included in endoscopists’ overall performance statistics.
- ENDOSCOPY
- CLINICAL DECISION MAKING
- MEDICAL STATISTICS
This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Statistics from Altmetric.com
Supplementary materials
Supplementary Data
This web only file has been produced by the BMJ Publishing Group from an electronic file supplied by the author(s) and has not been edited for content.
- Data supplement 1 - Online figure
- Data supplement 2 - Online table