Endoscopic closure of perforations caused by EMR in the stomach by application of metallic clips

Gastrointest Endosc. 2003 Jun;57(7):948-51. doi: 10.1016/s0016-5107(03)70051-0.

Abstract

Background: The number of complications associated with use of EMR for early-stage gastric cancer, including perforation, has increased with the increasing use of this procedure. Endoscopic clip application was performed in patients who sustained a perforation as a result of EMR for gastric neoplasm.

Patients and methods: Seven patients who underwent endoscopic application of metallic clips to close perforations were studied. The omental patch method was applied in one case with a large perforation.

Observations: In all patients, endoscopic clip application successfully closed the perforation of the stomach, which occurred after EMR. No patient required laparotomy.

Conclusions: The technique of endoscopic clip application might be useful for treatment of patients who sustain a perforation caused by EMR.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Digestive System Surgical Procedures / instrumentation*
  • Endoscopy, Gastrointestinal / adverse effects*
  • Female
  • Humans
  • Intraoperative Complications*
  • Male
  • Middle Aged
  • Stomach Neoplasms / surgery*